CCTV
        Samsung GVI
- Cámara Color
- Cámara Infrarojo
- Cámara día / noche
- Lente Motorizado
- Autodomo
- Autodomo Accesorios
- Cámaras Ip
- Cámaras Térmicas
- DVR
- Monitores
- Grabadores Ip
- DVR´S Análogos
        Honeywell
- Cámara Color
- DVR
        Accesorios
- Convertidores
- Fuentes de poder
- Housing
  Vipertek
- Vipertek
Deteción de incendio - Silent Knight
- Honeywell
- Accesorios
   Sistema de Alarma
- Paneles
- Detectores
- Contactos
- Accesorios
Control de Acceso
- Personal
- Vehicular
Detección Perimetral
- Cable Microfónico
- Cerco Eléctrico
- Control Telefónico
- Detectores de Metal
- Cables

 
   Honeywell
      Detección de Incendios > Honeywell (7 items)
Username Password
VISTA-250BP

ESPECIFICACIONES:
• Provides nine style-B hardwired zones
• Supports up to 241 additional zones using a built-in polling (multiplex) loop interface
• Supports up to 250 wireless zones using 5881 type RF receiver (fewer if using hardwired and/or polling loop zones)
• Provides 1 power-limited bell circuit delivering 1.7Amp (max) at 12Vdc.
• Provides the ability to control eight separate partitions independently, each functioning as if it had its own separate control
• Accommodates 250 user codes with seven authority levels
• Accommodates 32 keypad macro commands per system
• Keeps a log of up to 1,000 events
• VISTAView-100 CCTV support
• Supports up to 16 two-wire smoke detectors on zone 1
• Supports up to 50 latching-type glassbreak detectors on zone 8
• Zone 7 may be used for keyswitch arming/disarming
• Integrates with PassPoint access control systems to provide increased users, event log, and scheduling (up to 32 doors)
• Supports V-Plex addressable VISTAKey access control (up to 15 doors and 500 cards)
• Easily programmed and maintained by the newly upgraded Compass Windows-based downloader
• Supports up to 96 programmable relays
• Supports the ADEMCO 4286 VIP Module
• Programmable to meet SIA false alarm prevention specifications.
To meet UL approval forANSI/SIA CP-01-2000 order part number VISTA-128SIA

 
 

Partitioned Commercial Fire/Burglary
Alarm Control Panel

Descargar detalle técnico
 
VISTA-128B

ESPECIFICACIONES:
Provides nine style-B hardwired zones
• Supports up to 119 additional zones using a built-in polling (multiplex) loop interface
• Can control up to eight separate partitions independently, each functioning as if it had its own separate control
• Accommodates 150 user codes with seven authority levels
• Supports up to 128 wireless zones using a 5881 type RF receiver (fewer if using hardwired and/or polling loop zones)
• Supports the 5817CB Wireless Commercial Transmitter
• Supports the 5869 Wireless Commercial Burglary Hold-up switch
• Supports the 5881ENHC Wireless Commercial receiver
• Accommodates 32 keypad macro commands per system
• Keeps a log of up to 512 events
• Supports up to 16 two-wire smoke detectors on zone 1
• Supports up to 50 latching-type glassbreak detectors on zone 8
• Integrates with PassPoint access control to provide increased users, event log, and scheduling
• Supports addressable VistaKey access control (up to 8 doors)
• Easily programmed and maintained using Compass Windows-based downloader
• Supports the ADEMCO 4286 VIP Module

 
 

Commercial Burglary/CCTV and Access Control Platform

Descargar detalle técnico
 
5110XM

ESPECIFICACIONES:
• Five supervised style B zones
• One master code
• Five user codes
• Seven built-in LED indicators
• One notification appliance circuit
• Temporal code compliant
• Supervised digital dialer
• Optional panel door mounted silence/reset switch when AHJ approved ~
• Supports two-wire compatible smoke detector
• Supports up to four keypads
• Backup digital dialer built in
• Auxiliary form "C" relay
• Built-in warning buzzer•
• Programmable via 6139R alpha keypad or downloader
• Supports major communication formats
• UL864 Listed
• NFPA 72 compliant
• MEA Approved
• Upload/Download capable

 
 

Fire Alarm Communicator and DACT

Descargar detalle técnico
 
5192

ESPECIFICACIONES:
• Low profile design
• V-Plex™ addressable loop device
• Automatic maintenance reporting
• Available with integral heat sensor
• Simple 2 wire installation
• Tamper resistant
• DIP switch or serial number programmable
• Lines on existing or conventional wiring

 
 

Smoke detector

Descargar detalle técnico
 
ECO-1000

ESPECIFICACIONES:
• Sensores Fotoélectricos Térmicos (Fijos y Termovelocimétricos) y combinados
• Rango de Operación 10-30 Voltios DC
• Cabezas intercambiables
• Bases mara montajes como 2-Hilos 5-Hilos
• Ideales para usarse en los paneles de intrusión

 
 
 
BEAM1224(S)

ESPECIFICACIONES:
• 16 to 328 foot protection range
• Single-ended, reflective design
• User friendly alignment procedure
• 6 user selectable sensitivity levels
• Optional integral NFPA 72 sensitivity test feature
• Removable plug-in terminal blocks
• Digital display for easy alignment
• Built-in automatic gain control compensates for signal deterioration fromdust build-up
• Remote test station optional
• Paintable cover
• Easiest alignment in the industry

 
 

Single-ended Reflected Type Beam Smoke Detector

Descargar detalle técnico
 
MACROQUIL S.A. 2008   
Desarrollado por: Sambo web y multimedia